Friday, February 28, 2014

Weil mclain cga boiler firing issue

Weil Mclain CGa Boiler Firing Issue


I have a Weil Mclain CGa boiler that is only a couple of years old. I drained the boiler and shut it down over the summer, I just tried starting it up yesterday and I am having issues. First I flushed the whole system out and filled with new water. Second I lit the standing pilot without any issue. Then I turned power on to the boiler and adjusted the thermostat to a high enough temperature to kick the boiler on. Initially it turned on as expected, the circulator started pumping, the automatic vent damper opened up and the main burners kicked on. The system fired for a couple of minutes and then stopped. I checked the temperature gauge and the water reached about 120 degrees. The aquastat is set to 180 degrees. I felt the pipes coming out of the boiler and they were not warm. The circulator kept pumping. The only way I could get the system to fire again is by shutting it down by adjusting the thermostat lower, and letting it sit for about an hour. Once I adjusted the thermostat higher again the boiler would fire for a couple minutes and shut off again. I cannot get the boiler to fire long enough to heat the water to a hot enough temperature. Any ideas? Steve, before we get on to the firing problem, can I ask why you drained it when you shut it down? Not only is that not necessary, and makes all that extra work for you in the fall time, it is actually a bad thing. Here's why... when you run water in a closed heating system, all of the oxygen is driven out of the water and vented to the atmosphere. Water without oxygen will not rust or corrode anything. By draining the system and allowing all that air that is now in there is allowing rust and corrosion to form. Bottom line, just shut it off. Do not drain it. more later... There are a number of things that can cause this. In line with the gas valve are some safety switches. There are a 'SPILL SWITCH', a 'ROLLOUT SWITCH', and the switch inside the vent damper to prove it is open. You may also have a LWCO (Low Water Cut Off) switch installed. Any one of these tripping indicates that there is a problem... There could be rust and junk on top of the burners causing poor combustion and soot and rust in the flue passes causing poor draft which would trip the flame 'rollout'. There could be a (now dead) family of squirrels in your chimney that would cause flue gas to escape around the atmospheric vent on the flue pipe and trip the 'spill switch'. Your vent damper might be malfunctioning. If you have the optional LWCO, it could be sensing (either actually, or falsely) a low water condition. What is your skill level? Do you feel confident?








Related Posts:




  • Weil mclain he ii boiler

    Weil McLain HE II boilerI have a Weil McLain HE II boiler, it's about 8 yrs old, installed by me, all has been working well with it, however at the beginning of this heating season I have noticed...


  • Weil mclain 68 oil fired boiler efficiency

    Weil Mclain 68 oil fired boiler efficiencyHello and thanks in advance, I received this boiler as a gift from a heating contractor friend of mine as he went into retirement. Weil Mclain 68 rear flu...


  • Weil mclain gold oil boiler

    Weil Mclain Gold oil boilerWell this is driving me nuts, the boiler comes on when the thermostats are NOT calling for heat. I don't have an internal hot water heater so thats not it. I put in new...


  • Thermostat on water heater not working weil mclain gold plus 40

    Thermostat on Water Heater not working Weil Mclain Gold Plus 40Hi, I just moved into a house that has a Weil Mclain Gold Plus indirect water heater. I have the temperature set to the factory recom...


  • Troubleshooting a gas boiler pilot light issue

    Troubleshooting a Gas Boiler / Pilot Light Issue?Hello, This might be an easy question for most here to answer. I have experience with continuous pilots but not with direct ignitions so I hope tha...