Tuesday, February 25, 2014

Binks compressor parts

Binks Compressor Parts?


I inherited a Binks compressor over the weekend. Wired it up and it runs great but it build air VERY slowly and only ever reaches 40psi. The motor never shuts off because it never reaches full pressure. I am just wondering where I can find replacment parts for this thing. Thanks for any help you can give. Serial # 210-5 Model # 33-518 You cannot get an off the shelf kit for something like this anymore. If you are serious about a rebuild, you'll have to tear down the pump and find out what the problem is. Most likely it's in the top end, the head. The valves wear out and dont seat or get gummed up with carbon and dirt. Springs get weak, and so on. But it might be the rings, pistons and cylinder bores as well. All is fixable and replacable, depending on how much money and work you want to put into it. Start by studying this, if you haven't already: http://www.binks.com/Service%20Bulletins/77-0198r.pdf Good luck I too had a simular situation. I have two of the Binks units, one is a killer Model 33-1261 with a 350 the other is a 216. Both of these are Quincy compressor as is your. They are pressure lubricated rather than drip lubricated and you can still get parts needed to repair. Most likely your disk valves need service. The 210 is the Quincy compressor number. If you go to Mesa Equipment Supply Company web sight you can download the specs on the Quincy compressor and probably get parts from them.








Related Posts:




  • Buffalo tools compressor parts [Post relocated to its own thread]

    Buffalo Tools Compressor Parts [Post relocated to it's own thread]I am trying to fix a Buffalo Tools air compressor. Can't find a model number on it. It belongs to a family member and got damaged...


  • Air compressor repair

    Air compressor repairTry not to laugh so loud. I was given an old Craftsman air compressor that runs pretty good. It has a broken plastic part that sticks out of the side of the head on the pump....


  • Compressor replacement on trane

    Compressor replacement on TraneI have a 1999 3 ton trane, seer 12 condensor, which has not been cooling efficiently (seems like semi cold air). A technician came out 9 months ago due to same probl...


  • Condenser fan not spinning compressor trying

    Condenser fan not spinning, compressor trying5 yr old split Lennox unit. Noticed high temp in house. First checked interior fan - it was just recirculating room temp air. Then checked compressor u...


  • Air compressor with bad water problem

    Air compressor with bad water problem.I just bought a crasftmans 60 gal 3.1 hp. I ran about 40ft of redcopper pipping across my garage with two drops. Yet at my filter/regulator i get tons of...